SLA/6PRG/4PRG/10-30DC/-3AO [DIN] SLA Functional Safety Logic Solver and Alarm Input Description: Six Programmable Inputs for 0-25mA, 0-10V, RTD, T/C, Ohms, mV Output Description: Four Relay Outputs and Four Discrete Outputs Power Description: 4-Wire, 10-30VDC Options Description: Three Programmable Analog Outputs, any range between 0-20mA Housing Description: DIN-style housing mounts on 35mm Top Hat DIN-rails HART Signal Pass-through Capability: Yes For use in Safety Instrumented Systems (SIS): Yes Communication Protocol: MODBUS/TCP, Web Server Device Power: 4-Wire, 24VDC Line/Mains Powered Input: Programmable: All Input Types Number of Alarm/Relay Outputs: 1, 2, 3, 4, 8 Analog Output: Yes Integral Display: Yes Intrinsically-Safe Input Connections: No Configuration/Setup: PC Configurable, Ethernet Housing/Enclosure: DIN Rail Enclosure RoHS Compliant: Yes Additional Features: Alarm/Event Voting, Math/Logic, Redundant Inputs |
SPA2/HLPRG/4PRG/U/-AO [DIN] SPA2 Programmable Limit Alarm Trip Input Description: Programmable, any range within 0-50mA or 0-10V Output Description: Four Alarm Outputs Power Description: Universal Power, 21.6-375Vdc or 90-260Vac Options Description: Programmable Analog Output, any range between 0-20mA and 0-10V Housing Description: DIN-style housing mounts on 35mm Top Hat DIN-rails For use in Safety Instrumented Systems (SIS): No Device Power: Universal: 4-Wire 24DC/117VAC/230VAC Line/Mains Powered Input: Programmable, Current or Voltage, 4-20mA, 0-10VDC, 1-5VDC Number of Alarm/Relay Outputs: 1, 2, 3, 4 Analog Output: Yes Integral Display: Yes Intrinsically-Safe Input Connections: No Configuration/Setup: PC Configurable, USB Cable, Face-plate Configurable Housing/Enclosure: DIN Rail Enclosure Hazardous Area Certifications: Non-Incendive/Div. 2, Zone 2 RoHS Compliant: Yes |
STA/TPRG/3PRG/U/-AO [DIN] STA Functional Safety Limit Alarm Trip Input Description: Programmable Input for RTD, T/C, Ohms, mV or Potentiometer Output Description: Two Alarm Outputs, One Fault Relay Power Description: Universal Power, 21.6-375Vdc or 90-260Vac Options Description: Programmable Analog Output, any range between 0-20mA and 0-10V Housing Description: DIN-style housing mounts on 35mm Top Hat DIN-rails For use in Safety Instrumented Systems (SIS): Yes Device Power: Universal: 4-Wire 24DC/117VAC/230VAC Line/Mains Powered Input: Programmable, RTD, T/C, mV, Ohms, Potentiometer Number of Alarm/Relay Outputs: 1, 2, 3 Analog Output: Yes Integral Display: Yes Intrinsically-Safe Input Connections: No Configuration/Setup: PC Configurable, USB Cable, Face-plate Configurable Housing/Enclosure: DIN Rail Enclosure Hazardous Area Certifications: Non-Incendive/Div. 2, Zone 2 RoHS Compliant: Yes |
SLA/6PRG/4PRG/10-30DC [DIN] SLA Functional Safety Logic Solver and Alarm Input Description: Six Programmable Inputs for 0-25mA, 0-10V, RTD, T/C, Ohms Output Description: Four Relay Outputs and Four Discrete Outputs Power Description: 4-Wire, 10-30VDC Housing Description: DIN-style housing mounts on 35mm Top Hat DIN-rails HART Signal Pass-through Capability: Yes For use in Safety Instrumented Systems (SIS): Yes Communication Protocol: MODBUS/TCP, Web Server Device Power: 4-Wire, 24VDC Line/Mains Powered Input: Programmable: All Input Types Number of Alarm/Relay Outputs: 1, 2, 3, 4, 8 Integral Display: Yes Intrinsically-Safe Input Connections: No Configuration/Setup: PC Configurable, Ethernet Housing/Enclosure: DIN Rail Enclosure RoHS Compliant: Yes Additional Features: Alarm/Event Voting, Math/Logic, Redundant Inputs |
SRM/CC/3RO/24DC [DIN] SRM Safety Relay Module Input Description: Contact Closure Output Description: Three Relay Outputs Power Description: 4-Wire, 24VDC Housing Description: DIN-style housing mounts on 35mm Top Hat DIN-rails For use in Safety Instrumented Systems (SIS): Yes Device Power: 4-Wire, 24VDC Input: Contact Closure Number of Alarm/Relay Outputs: 1, 2, 3 Analog Output: No Integral Display: No Intrinsically-Safe Input Connections: No Configuration/Setup: Face-plate Configurable Housing/Enclosure: DIN Rail Enclosure RoHS Compliant: Yes |
SPA2IS/HLPRG/4PRG/U/-AO [DIN] SPA2IS Associated IS Programmable Limit Alarm Trip Input Description: Programmable, any range within 0-50mA or 0-10V Output Description: Four Alarm Outputs Power Description: Universal Power, 21.6-375Vdc or 90-260Vac Options Description: Programmable Analog Output, any range between 0-20mA and 0-10V Housing Description: DIN-style housing mounts on 35mm Top Hat DIN-rails For use in Safety Instrumented Systems (SIS): No Device Power: Universal: 4-Wire 24DC/117VAC/230VAC Line/Mains Powered Input: Programmable, Current or Voltage, 4-20mA, 0-10VDC, 1-5VDC Number of Alarm/Relay Outputs: 1, 2, 3, 4 Analog Output: Yes Integral Display: Yes Intrinsically-Safe Input Connections: Yes Configuration/Setup: PC Configurable, USB Cable, Face-plate Configurable Housing/Enclosure: DIN Rail Enclosure Hazardous Area Certifications: Non-Incendive/Div. 2, Zone 2 RoHS Compliant: In Process |
NCS EMM -MAA NCS NET Concentrator System with Multipoint Analog Alarm Input Description: Programmable: Current, Voltage, RTD, T/C, mV, Ohms, Potentiometer, Discrete/Digital Contact Output Description: Eight Relay Outputs Power Description: 20-30DC Options Description: -MAA Multipoint Analog Alarm Housing Description: DIN-style housing mounts on 35mm Top Hat DIN-rails For use in Safety Instrumented Systems (SIS): No Device Power: 24VDC Input: Universal: All Input Types, Discrete/Digital Contact Number of Alarm/Relay Outputs: 8 Analog Output: No Integral Display: No Intrinsically-Safe Input Connections: No Configuration/Setup: PC Configurable, Ethernet Housing/Enclosure: DIN Rail Hazardous Area Certifications: Non-Incendive/Div. 2, Zone 2 RoHS Compliant: Yes |
ECA/4-20mA/DH1H1/24DC/-TX [DIN] ECA Current and Voltage Limit Alarm Trip Input Description: 4-20mA Output Description: Field Configurable, set as Dual, High/High, Failsafe Power Description: 4-Wire, 24VDC Options Description: 24V transmitter excitation for powering a 2-wire transmitter Housing Description: Universal DIN-style housing mounts on G-type and Top Hat DIN-rails For use in Safety Instrumented Systems (SIS): No Device Power: 4-Wire, 24VDC Input: 4-20mA Number of Alarm/Relay Outputs: 1, 2 Analog Output: No Integral Display: No Intrinsically-Safe Input Connections: No Housing/Enclosure: DIN Rail Enclosure RoHS Compliant: No |
330R2/PRG/2PRG/HIACDC/-AO-TX [P] 330R2 1/8 DIN Process and Temperature Panel Meter & Alarm Input Description: 0-20mA, 4-20mA, ±20mA, 0-5V, 1-5V, 0-10V, ±10V, TC & RTD Output Description: Two Alarm Outputs, Analog Output Power Description: 4-Wire, 85-265VAC or 90-265VDC Options Description: Isolated analog output and 24V transmitter excitation for powering connected transmitter Housing Description: 1/8 DIN Panel mount, corrosion resistant Nema 4X, IP65 faceplate For use in Safety Instrumented Systems (SIS): No Device Power: 4-Wire, 85-265VAC or 90-265VDC Input: Programmable, Current, Voltage, RTD, Thermocouple Number of Alarm/Relay Outputs: 1, 2 Analog Output: Yes Integral Display: Yes Intrinsically-Safe Input Connections: No Configuration/Setup: PC Configurable, USB Cable, Face-plate Configurable Housing/Enclosure: 1/8 DIN Panel mount, corrosion resistant Nema 4X, IP65 faceplate |
330R2/PRG/2PRG/LOACDC/-AO [P] 330R2 1/8 DIN Process and Temperature Panel Meter & Alarm Input Description: 0-20mA, 4-20mA, ±20mA, 0-5V, 1-5V, 0-10V, ±10V, TC & RTD Output Description: Two Alarm Outputs, Analog Output Power Description: 4-Wire, 12-24VAC or 12-36VDC Options Description: Isolated analog output Housing Description: 1/8 DIN Panel mount, corrosion resistant Nema 4X, IP65 faceplate For use in Safety Instrumented Systems (SIS): No Device Power: 4-Wire, 12-24VAC or 12-36VDC Input: Programmable, Current, Voltage, RTD, Thermocouple Number of Alarm/Relay Outputs: 1, 2 Analog Output: Yes Integral Display: Yes Intrinsically-Safe Input Connections: No Configuration/Setup: PC Configurable, USB Cable, Face-plate Configurable Housing/Enclosure: 1/8 DIN Panel mount, corrosion resistant Nema 4X, IP65 faceplate RoHS Compliant: Yes |